POWERbreathe KHP2 IMT for Patients
$949.95
The POWERbreathe KHP2 is a hand held, electronic tapered loading, inspiratory muscle training, assessment and monitoring device. It has been developed specifically for patients to use for pre-operative conditioning, as part of their rehabilitation, or for symptom relief of lung function limiting diseases and conditions.
In stock (can be backordered)
Manufacturer Warranty
CloseReturn Policy
30-Day Return Window. Returns are accepted within 30 days of delivery for items that remain new and unopened.
Unopened condition required. Security seals must remain intact and packaging must not be opened. Items must be returned in original, unused condition for full product credit.
All law labels, identification labels, manuals, and original packaging must remain attached and undamaged. Please pack returns carefully in a secondary shipping box to prevent damage in transit.
If an item is returned opened, used, or not in resellable condition, the return will not be accepted. You will be contacted regarding return shipping fees to have the item shipped back to you.
If we do not receive instructions regarding return shipment within 30 days, you authorize us to dispose of the item on your behalf.
International orders are final sale. Orders shipped outside of Canada are not eligible for return or exchange.
For complete eligibility requirements and return instructions, please review our Return & Exchange Policy.
Following a breathing consultation with a healthcare professional using the Powerbreathe KH2 with Breathe-Link® Medic Live Feedback Software, a patient may then use the KHP2 at home, as part of their on-going treatment plan.
A healthcare professional is able to review patient progress by tracking up to 36 of the patient’s training sessions which the KHP2 is able to store.
Clinical research shows the KHP2 has high patient motivation and adherence to training thanks to the on-screen feedback. It’s this immediate feedback that produces a high compliance (90%+) and significantly improves breathing muscle strength and stamina.
Features
- Manual training intensity option: 5-200 cmH2O.
- Auto-optimizing IMT: Matches the strength profile of the inspiratory muscles.
- Training intensity selector: Option to be set to ‘auto’ or ‘manual’ for increasing/decreasing load intensity (cm H2O).
- Breathing Pacing Guidance: An audible beep guides breathing at an appropriate rate.
- Training results: Load (cmH20), Power (Watts), Inhaled Volume (Litres) and Energy (Joules).
- Training History: Graphical history of load, power and volume for the previous 36 training sessions.

Measurement Validity
The following study concludes that the K-Series device “provides automatically processed and valid estimates of physical units of energy during loaded breathing tasks…”
Measurement validity of an electronic inspiratory loading device during a loaded breathing task in patients with COPD
The following study suggests that S-Index® might be more appropriate for measuring inspiratory muscle performance than the currently most used test, PImax…
Assessment of Maximum Dynamic Inspiratory Pressure
The following study finds that “It is feasible and reliable to evaluate the maximum repetition of inspiratory muscles in healthy individuals…”
What’s In the Box
- POWERbreathe IMT Device & User Manual: The K-Series is manufactured in a hygienic environment but is not considered ‘sterile’. The mouthpiece must be cleaned prior to use. The box is sealed to maintain hygiene and cannot be returned if the tamper seal is broken. Please read the user manual carefully before using.
- USB Charger & Cable: The device comes with a charging plug and charging cable.
- Valve Head, Mouthpiece & Nose Clip & Spacer: Mouthpiece: Material – TPE (Thermoplastic elastomers). The nose clip helps the user to breathe through the mouth rather than the nose, thus improving the training effects. However, it is not essential to use. The Spacer can be used in conjunction with a Respiratory Mask and Oxygen Mask Adapter for those patients on oxygen.
- Cradle, Storage Pouch & Cleansing Tablets*: The cradle may be used to house the device while charging. The pouch ensures everything stays stored away in a good, clean condition. Four cleansing tablets are included. Once a week the device should be soaked in this mild cleansing solution – only 1 tablet is required each time.
Documents
PowerBreathe KHP2 Medical Brochure
PowerBreathe Health & Medical Brochure 2024
Videos
Maximal Inspiratory Pressure Measurement Using the PowerBreathe KH2
Respiratory Muscle Training Using the PowerBreathe KH2
Perform a Correct Breathing Technique with the PowerBreathe KH2 IMT
| Weight | 700 g |
|---|---|
| Dimensions | 22 × 16 × 8 cm |
| Country of Origin | Taiwan |
| HS Code | 90192090 |
| Availability |
Now available in-store at 22635 Komoka Road Komoka N0L1R0 Powered With Oliver Pos |
|---|
Precautions & Contraindications
POWERbreathe IMT breathing training is drug-free, suitable for almost anyone and should cause no harmful side effects when used properly. Please read the following precautions and contraindications to ensure that POWERbreathe IMT is used safely and appropriately. You must always consult your healthcare professional before embarking on any new form of exercise and this includes POWERbreathe breathing training.
Precautions:
- The patient must not make changes to any prescribed medication or prescribed treatment program without consulting their doctor.
- Do not use the POWERbreathe whilst taking part in other activities where you may become distracted, such as walking, running and driving.
- POWERbreathe should not be used if the patient is suffering from a ruptured eardrum or any other condition of the eardrum.
- It is not recommended to use POWERbreathe if you have suffered from or are likely to suffer from Costochondritis.
- To prevent the potential transmission of infections, we recommend that POWERbreathe is not shared with other users, including family members.
- This product is not intended to diagnose, treat, cure or prevent any disease.
- POWERbreathe is designed for exercising the inspiratory muscles only. No other use is intended or implied.
- Anyone who is under the age of 16 should only use POWERbreathe with supervision from an adult. POWERbreathe contains small parts and is not suitable for children under 7 years.
- Whilst training with POWERbreathe the patient should feel resistance when inhaling but it should not be painful. If the patient feels pain whilst using POWERbreathe they should stop immediately and consult their doctor.
- Some users may experience slight ear discomfort when training with POWERbreathe, especially if they are recovering from a cold. This is caused by inadequate equalization of pressure between the mouth and ears. If symptoms persist, patients should consult their doctor.
- If a patient is suffering from a cold, sinusitis or respiratory tract infection, we advise that they do not use POWERbreathe until symptoms have disappeared.
- If you start to feel dizzy using POWERbreathe IMT, please pause until recovered and take longer gaps between breaths.
Healthcare Professional should take into consideration the following conditions before patients use POWERbreathe:
- A history of spontaneous pneumothorax (a collapsed lung that was not due to traumatic injury e.g. broken rib), as it may lead to a recurrence of the condition.
- Pulmonary hypertension or large bullae on chest x-ray.
- Marked osteoporosis with history of rib fractures.
- Desaturation during or following IMT (<94%).
Contraindications
Inspiratory muscle training, such as training with POWERbreathe, is not recommended for patients with certain conditions, including the following:
- Patients who have undergone recent abdominal surgery and those with an abdominal hernia.
- Asthma patients who have a very low symptom perception and suffer from frequent, severe exacerbations or with an abnormally low perception of dyspnoea
- If a patient is suffering from a ruptured eardrum or any other condition of the ear
- Patients with marked elevated left ventricular end-diastolic volume and pressure
- Patients with worsening heart failure signs and symptoms after RMT / IMT
- If you are suffering from a cold, sinusitis or respiratory tract infection, we advise that you do not use your POWERbreathe IMT device
You may also like…
POWERbreathe K5 IMT with Advanced Breathe-Link Software
Out of stock
$999.95POWERbreathe Spacer
In Stock
$3.69POWERbreathe Trysafe Filter
In Stock
$3.69POWERbreathe Medic Plus Inspiratory Muscle Training (IMT)
In Stock(28 Units)
$129.95POWERbreathe Plus Inspiratory Muscle Trainer (IMT) – Light Resistance
In Stock(50 Units)
$129.95POWERbreathe Plus Inspiratory Muscle Trainer (IMT) – Medium Resistance
In Stock(10 Units)
$129.95Related products
Bauerfeind LordoLoc Lower Back Brace
In Stock
$267.00Original McKenzie Lumbar Night roll
In Stock
$55.95 – $69.95Price range: $55.95 through $69.95Bauerfeind GenuTrain Knee Brace (New Edition)
In Stock(2 Units)
$200.00DonJoy Lateral J Patella Knee Brace
In Stock
$134.95DonJoy OA Reaction Web Unloader Knee Brace
In Stock
$234.95Elasto-Gel Neck/Back Support Roll
In Stock
$59.95 – $79.50Price range: $59.95 through $79.50