MedX Rehab Laser Console System

$5,599.00

The MedX Rehab Laser Console System 3118 is a professional low-level laser therapy platform proudly made in Canada. It includes the MedX Laser Console (MBM1100N), a 450 mW tethered laser, and two 1000 SLD clusters to support both focused and large-area photobiomodulation treatments.

This system is trusted worldwide for its clinical accuracy, durability, and consistent results in pain relief, tissue healing, and rehabilitation programs.

Available, but this item may take 1-3 weeks to ship.

MedX cold laser systems
Description

MedX Rehab Laser Console System 3118

The MedX Rehab Laser Console System 3118 is a professional low-level laser therapy (LLLT) platform designed for clinical rehabilitation settings and advanced home programs. It provides consistent phototherapy to help reduce pain, improve circulation, and support tissue repair for musculoskeletal and soft tissue conditions. MedX systems are known for their durability, precision, and ease of use in clinical environments.

MedX Treatment Head Options

LD Clusters (Super-Luminous Diodes)

  • Use high-intensity LEDs that emit broad, non-coherent therapeutic light.
  • Cover large or diffuse areas such as the shoulder, low back, or major muscle groups.
  • Provide gentle warmth and allow sweeping motions across tissue.
  • Support treatment of general pain, stiffness, and soft tissue healing.

Tethered Laser Applicator

  • Class IIIb handheld laser delivering coherent, collimated light for deeper penetration.
  • Ideal for treating trigger points, tendons, ligaments, and small joint areas.
  • Produces a precise, non-thermal beam for focused application.
  • Supports targeted photobiomodulation for specific treatment zones.

Quick Compare

FeatureLD ClustersTethered Laser Applicator
Light TypeBroad, non-coherent LEDCoherent, collimated laser
Treatment AreaLarge / diffuseSmall / focal
Application SpeedFaster, sweeping passesSlower, precise targeting
Perceived SensationGentle warmthNon-thermal pinpoint beam
Best ForBack, shoulder, larger muscle groupsTrigger points, tendons, small joints

What’s Included

  • MedX Laser Console (MBM1100N)
  • Rehab Tethered Laser (450 mW LCT450)
  • Two SLD Clusters (MCT1001)
  • Power supply and power cord
  • Treatment Guide
  • Operating Guide
  • Two pairs of laser safety goggles (MPG01)

Key Features and Benefits

  • Supports both deep, focused laser therapy and broad-area LED cluster treatments.
  • 450 mW handheld laser provides strong and consistent output for targeted penetration.
  • Dual SLD clusters help reduce treatment time with wide-area coverage.
  • Three accessory ports allow flexible combinations of applicators.
  • Evidence-based photobiomodulation supports circulation, tissue repair, and inflammation reduction.
Made in Canada IconThe MedX Rehab Laser Console System 3118 is manufactured in Canada. MedX is recognized globally for high-quality engineering, clinical accuracy, and dependable performance.

Applications

The MedX Rehab Laser Console System can support treatment of:

  • Musculoskeletal pain and inflammation
  • Soft tissue injuries and repetitive strain
  • Joint irritation and arthritis
  • Sports injuries and post-surgical recovery

Why Choose MedX?

MedX is a leader in photobiomodulation therapy. The 3118 system offers reliable energy delivery, simple menu navigation, and flexible treatment options. It is suitable for multi-disciplinary clinics that require a dependable laser therapy platform for busy practice environments.

MedX Laser Console (MBM1100N)

  • Controls all connected laser and LED accessories.
  • Guided mode assists with treatment parameter setup.
  • Manual mode supports quick custom programming.
  • Displays time and energy delivered for each active port.
  • Supports simultaneous use of up to three accessories.

Rehab Tethered Laser (LCT450)

The handheld laser uses three GaAlAs diodes and a guide light to deliver 450 mW of focused energy. The handpiece has an independent ON/OFF switch for easy control during application.

SLD Cluster Applicators (MCT1001)

The SLD cluster combines infrared (870 nm) and visible red (633 nm) wavelengths for wide-area illumination. Two clusters can be strapped on for hands-free treatment, and the console automatically stops output when the session ends.

MedX Rehab Console System Canada

All systems include access to MedX Health’s photobiomodulation education resources.

Return on Investment for Clinics

The MedX Rehab Console System provides strong value for physiotherapy, chiropractic, massage therapy, and sports medicine clinics. At the current price of $4,599, cost recovery can occur quickly through billable photobiomodulation sessions.

Based on a typical $75 treatment fee:

  • 4 treatments per month: approx. 15–16 months to recover cost
  • 6 treatments per month: approx. 10 months
  • 8 treatments per month: approx. 7–8 months
  • 10 treatments per month: approx. 6 months
  • 12–15 treatments per month: approx. 4–5 months

This offers many clinics one of the fastest and most predictable returns on therapeutic equipment in modern rehabilitation practice.

Calibration, Testing & Service Guidance

MedX recommends that clinical laser systems be professionally tested and calibrated yearly after the first three years of use. Calibration helps verify laser output accuracy and ensures consistent treatment performance over time.

All official calibration, testing, servicing, and repair work is handled directly by MedX Health. Clinics and users can contact MedX to book testing services, arrange repairs, or request technical support:

  • Website: MedX Health Contact Portal
  • Phone: +1 (226) 286-4558
  • Email: info@medxhealth.com
  • Head Office: 1495 Bonhill Road, Unit #1, Mississauga, ON, Canada L5T 1M2

If you are unsure whether your MedX laser requires calibration or testing, our team and MedX Health can help review usage history and provide guidance.

Documents

DocumentTypeDownload
MedX Rehab Console Operating GuidePDFDownload
Photobiomodulation Info and Peer ReviewPDFDownload

Videos

Unboxing the MedX Rehab Laser Console System

Frequently Asked Questions

Click on the question to reveal the answer!
What applicators are included with the MedX Rehab Laser Console System 3118?

The system includes a handheld laser applicator with three 450 mW GaAlAs diodes (808 nm) and two hands-free Super-Luminous Diode (SLD) cluster heads, each 1000 mW, combining visible red (633 nm) and near-infrared (870 nm) light for broad-area treatment.

How many output ports does the console provide?

The console features three output ports, allowing clinicians to use multiple applicators at the same time—for example, both SLD clusters and the laser applicator—to treat several areas in one session efficiently.

Can the SLD clusters be used hands-free?

Yes. Each cluster head includes flexible straps for hands-free application, enabling unattended therapy while the console tracks time and energy delivered for each active port.

What is the difference between the laser applicator and the SLD clusters?

The laser applicator emits a focused, coherent Class IIIb laser beam for precise deep-tissue therapy. The SLD clusters emit non-coherent, broad-area light for surface and mid-depth coverage. Using both allows targeted and general treatment within the same session.

Are protective goggles required when using the system?

Yes, for the laser applicator component. Because it emits a coherent Class IIIb beam, both clinician and patient should wear laser safety glasses. The SLD clusters do not typically require goggles but should still follow standard light-safety precautions.

Additional information
Weight3858 g
Dimensions50 × 41 × 16 cm
Country of OriginCanada
Availability Now available in-store at
22635 Komoka Road Komoka N0L1R0

Powered With Oliver Pos

Frequently Asked Questions
Click on the question to reveal the answer!
What applicators are included with the MedX Rehab Laser Console System 3118?

The system includes a handheld laser applicator with three 450 mW GaAlAs diodes (808 nm) and two hands-free Super-Luminous Diode (SLD) cluster heads, each 1000 mW, combining visible red (633 nm) and near-infrared (870 nm) light for broad-area treatment.

How many output ports does the console provide?

The console features three output ports, allowing clinicians to use multiple applicators at the same time—for example, both SLD clusters and the laser applicator—to treat several areas in one session efficiently.

Can the SLD clusters be used hands-free?

Yes. Each cluster head includes flexible straps for hands-free application, enabling unattended therapy while the console tracks time and energy delivered for each active port.

What is the difference between the laser applicator and the SLD clusters?

The laser applicator emits a focused, coherent Class IIIb laser beam for precise deep-tissue therapy. The SLD clusters emit non-coherent, broad-area light for surface and mid-depth coverage. Using both allows targeted and general treatment within the same session.

Are protective goggles required when using the system?

Yes, for the laser applicator component. Because it emits a coherent Class IIIb beam, both clinician and patient should wear laser safety glasses. The SLD clusters do not typically require goggles but should still follow standard light-safety precautions.

What types of conditions can be treated with this system?

The MedX 3118 is indicated for musculoskeletal pain management, inflammation reduction, wound healing, and improved tissue recovery following injury or surgery. It is also used in physiotherapy, chiropractic, and sports medicine clinics for chronic pain and soft-tissue repair.

How does the console determine treatment time and energy dose?

The console automatically calculates total joules delivered based on power, mode, and time selected. Each port displays live energy output and stops automatically when the programmed dose is reached.

Can the system run continuous or pulsed modes?

Yes. Clinicians can choose continuous mode for chronic or deep-tissue pain and pulsed mode for acute injuries or sensitive tissues. Pulsed mode helps minimize thermal buildup during treatment.

What are the recommended energy dose ranges?

Typical settings are 4–8 J/cm² for superficial tissues and 8–12 J/cm² for deeper structures. The system’s display ensures accurate dosage and consistency between treatments.

How often should the system be calibrated?

Annual calibration is recommended to confirm diode accuracy and maintain optimal performance. Regular maintenance ensures consistent power output and compliance with safety standards.

Can all three applicators be used simultaneously?

Yes. Clinicians can operate multiple ports at once—for example, using both SLD clusters on large muscle groups and the laser probe on a focal trigger point. Each port is independently monitored for energy and time.

What advantages come from combining laser and SLD therapy?

Combining both light sources allows for dual-depth treatment—laser energy reaches deeper structures while SLD clusters provide surface-level coverage. This approach enhances outcomes and reduces total treatment time.

How does the console maintain dose accuracy across multiple ports?

Each output port is microprocessor-controlled with independent timers and energy counters. This ensures accurate, reproducible treatment regardless of how many probes are active.

What safety interlocks are built into the system?

The console includes interlocks that automatically disable emission if a probe disconnects, and visual indicators confirm active channels. Audible alerts signal session completion or errors for added safety.

How can treatment parameters be saved or recalled?

Clinicians can store custom protocols within the console memory, allowing quick setup for repeat patients and consistent application of evidence-based settings.

How often should the system be serviced?

The system should be inspected annually and cleaned after each use. Keeping optics clear and cables untangled helps extend diode life and maintain consistent energy output.

Is the MedX 3118 compatible with older MedX probes?

Yes. It is compatible with most MedX laser and SLD probes that use the same connector type. Existing applicators can be verified and recalibrated for use with the 3118 console.

What are the typical treatment times?

Most treatments last 1–3 minutes per point for laser probes and 5–10 minutes for larger areas using SLD clusters. The system automatically stops when the programmed energy dose is delivered.

What makes the MedX 3118 superior to portable laser units?

It provides triple-port operation, energy feedback, customizable protocols, and dual light modalities—offering greater flexibility, faster treatments, and higher clinical efficiency than smaller single-probe devices.

What training is recommended for clinicians new to laser therapy?

Clinicians should complete a recognized photobiomodulation or laser safety course covering parameters such as wavelength, power density, energy dosage, and contraindications. This ensures consistent, safe, and effective outcomes.

Do MedX laser devices need calibration or testing, and who performs it?

Yes. MedX recommends that clinical laser systems be professionally tested and calibrated annually starting in year three of use. This ensures that output levels remain accurate for safe and effective treatment. MedX Health performs all official calibration, testing, and repairs directly through their technical service department. Patients and clinics can contact MedX for service support, testing requests, or repair arrangements via their website, phone, or email.